Document ID (ISN) | 26768 |
CIS number |
77-402 |
ISSN - Serial title |
0010-244X - Cahiers des Comités de prévention du bâtiment et des travaux publics |
Year |
1976 |
Convention or series no. |
|
Author(s) |
Fiche de sécurité G.105, Organisme professionnel de prévention du bâtiment et des travaux publics, Issy-les-Moulineaux, June 1976. |
Title |
Provisional electrical installations for worksite illumination |
Original title |
Installation électrique provisoire pour l'éclairage des chantiers. [in French] |
Bibliographic information |
May-June 1976, No.3, 6p. (detachable insert). 5 ref. |
Abstract |
Contents of this technical data note: purpose of lighting of construction and civil engineering worksites, not including underground worksites (normal and emergency lighting); characteristics of worksite lighting installations (general; zones to be illuminated); different types of luminaires and accessories; illumination level (general lighting, functional exterior and interior lighting; general provisions concerning the electrical installation (choice of voltage, type of protection and cables; electrical installation of dependent premises (offices, storerooms, etc.)); emergency lighting (standby generating unit, central storage batteries, storage or dry battery lamps; maintenance). |
Descriptors (primary) |
France; artificial lighting; construction sites; temporary electrical installations |
Descriptors (secondary) |
illumination levels; electric lighting equipment; data sheet; safety lighting; construction industry; electrical safety |
Document type |
F - Information notes, codes of practice, standards |
Subject(s) |
Lighting, colour and vision
|
Broad subject area(s) |
|
Browse category(ies) |