ILO Home
Go to the home page
Site map | Contact us Français | Español

CISDOC database

Document ID (ISN)109037
CIS number 09-123
ISSN - Serial title 1545-9624 - Journal of Occupational and Environmental Hygiene
Year 2008
Convention or series no.
Author(s) Phalen R., Hee S.Q.
Title A moving robotic hand system for whole-glove permeation and penetration: Captan and nitrile gloves
Bibliographic information Apr. 2008, Vol.5, No.4, p.258-270. Illus. 39 ref.
Abstract The aim of this study was to develop a robotic hand to test the influence of hand movement on the permeation and penetration of captan through disposable nitrile rubber gloves. Permeation of an aqueous emulsion (217mg/mL) of captan was tested at 35°C. A surface wipe technique was used to collect captan from the inner surface of the exposed gloves. Findings are discussed. It is suggested that future research should continue to investigate the influence of hand movement and additional work factors on the permeation, penetration and physical integrity of protective gloves.
Descriptors (primary) protective gloves; captan; permeability testing; robots; nitrile rubber
Descriptors (secondary) exposure evaluation; statistical evaluation; tests on models; hand and arm protection
Document type D - Periodical articles
Country / State or ProvinceUSA
Subject(s) Agriculture, fishing, animal husbandry
Toxic and dangerous substances
Broad subject area(s) Chemical safety
Browse category(ies) Hand and arm protection
Amides